{"id":38,"date":"2017-02-13T19:57:39","date_gmt":"2017-02-13T19:57:39","guid":{"rendered":"http:\/\/eequalspi.com\/?p=38"},"modified":"2017-02-14T05:21:29","modified_gmt":"2017-02-14T05:21:29","slug":"wherein-the-tubes-go-tink","status":"publish","type":"post","link":"https:\/\/eequalspi.com\/index.php\/2017\/02\/13\/wherein-the-tubes-go-tink\/","title":{"rendered":"Wherein the tubes go &#8216;tink&#8217;"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p>About a month ago, I was watching TV. As usual my IN-13 VU-Meter was dutifully bouncing away with the dialog.<\/p>\n<p>Out of nowhere, one of the tubes made a &#8220;tink&#8221; sound and the current control went away &#8212; the tube stayed ignited, but the &#8220;bar&#8221; was stuck at the bottom.<\/p>\n<p>I noticed that the spacer at the far end of the tube was swinging freely, unlike the other, functional tube. Clearly, something had failed &#8212; it appeared that the IN-13&#8217;s control cathode had eroded and snapped. Chalking it up to a one-off failure, I dug into my spare nixie box and swapped out the tube.<\/p>\n<p>About a week later, the second tube exhibited exactly the same behavior! This was not a one off, but an early failure mode of the tubes. While a year and a half of use seems almost acceptable, I had expected much more life out of these tubes. Suffice it to say, the game was afoot.<\/p>\n<p>My first stop was the best Nixie forum on the internet, <a href=\"https:\/\/groups.google.com\/forum\/#!forum\/neonixie-l\">Neonixie-l<\/a>. Given the circuit schematic and my description, they were as baffled as I was &#8211; these tubes generally last much longer than I had experienced.<\/p>\n<p>Doing a little analysis of my circuit, the conclusion was that the most current my circuit could drive through the tubes was 10mA, which matched my own measurements. Unfortunately, the <a href=\"http:\/\/tubehobby.com\/datasheets\/in13.pdf\">datasheet<\/a> translated by tubehobby indicated that the maximum current through the tubes should be about 5mA. More current would shorten the lifespan of thetubes non-linearly, so some investigation was warranted.<\/p>\n<p>To the bench!<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-42\" src=\"http:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/image-1024x768.jpeg\" alt=\"\" width=\"584\" height=\"438\" srcset=\"https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/image-1024x768.jpeg 1024w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/image-300x225.jpeg 300w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/image-768x576.jpeg 768w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/image-1200x900.jpeg 1200w\" sizes=\"auto, (max-width: 584px) 85vw, 584px\" \/><\/p>\n<p>Figure 1: The setup. Multimeter, Function gen, DC power supply. Not pictured, scope, second function generator with AM input.<\/p>\n<p>Investigation steps:<br \/>\n1. Scope HV line (HV supply is <a href=\"http:\/\/www.tayloredge.com\/storefront\/SmartNixie\/DataSheets\/Datasheet_1363-1364.pdf\">TES 1364<\/a> module)<br \/>\n2. Multimeter on 220\u03a9 shunt resistor to get I_control<br \/>\n3. Input AC Signal &#8212; steady 10kHz, varous levels<br \/>\n4. Input AC Modulation signal &#8212; 10kHz AM&#8217;d 100% depth, 1Hz<br \/>\n5. DC Signal Input &#8212; remove Microcontroller and input DC to 100k\u03a9 resistor LPF before the voltage follower.<\/p>\n<p>Results:<br \/>\n1. HV Line, no input signal: Mean = 143V, V_pp = 8V<br \/>\n2. HV Line, full scale input signal (1.8V PP 10kHz sine wave &#8212; to front end): Mean = 143V, Vpp = 9V<br \/>\n3. Measure control current full system, using AC signal input:<br \/>\nI_shunt, no signal = 1mA (micro is still here, did not scope micro, but I suspect it was putting out a small nonzero PWM value)<br \/>\nI_shunt, full scale = 11.5mA<br \/>\n4. Measure control current, DC injection to IN-13 driver:<\/p>\n\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Vin (V)<\/th><th class=\"column-2\">I_shunt (mA)<\/th><th class=\"column-3\">Col. Length (cm)<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">6<\/td><td class=\"column-2\">13.9<\/td><td class=\"column-3\">11<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">5<\/td><td class=\"column-2\">11.4<\/td><td class=\"column-3\">11<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">4.5<\/td><td class=\"column-2\">10.9<\/td><td class=\"column-3\">11<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">4<\/td><td class=\"column-2\">9.4<\/td><td class=\"column-3\">10<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">2<\/td><td class=\"column-2\">4.9<\/td><td class=\"column-3\">5<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">1<\/td><td class=\"column-2\">2.41<\/td><td class=\"column-3\">2.5<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">0<\/td><td class=\"column-2\">0.045<\/td><td class=\"column-3\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache -->\n<p>I also measured the current through the cathode resistor (220k in series with the non-control cathode to ground):<\/p>\n\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Vin (V)<\/th><th class=\"column-2\">I_cath (mA)<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0<\/td><td class=\"column-2\">0.04<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">0.5<\/td><td class=\"column-2\">0.26<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">2<\/td><td class=\"column-2\">0.38<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">4.5<\/td><td class=\"column-2\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-2 from cache -->\n<p>Under normal operation, the tubes will never see more than ~11mA, which is substantially higher than the 5mA expected max current to get the full scale, and these tubes have seen a many of hours of burn in.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-41\" src=\"http:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.53.26-1024x768.jpeg\" alt=\"\" width=\"553\" height=\"415\" srcset=\"https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.53.26-1024x768.jpeg 1024w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.53.26-300x225.jpeg 300w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.53.26-768x576.jpeg 768w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.53.26-1200x900.jpeg 1200w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.53.26.jpeg 1600w\" sizes=\"auto, (max-width: 553px) 85vw, 553px\" \/><\/p>\n<p>Figure 2: 5mA, should produce full scale.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-40\" src=\"http:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.54.03-1024x768.jpeg\" alt=\"\" width=\"840\" height=\"630\" srcset=\"https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.54.03-1024x768.jpeg 1024w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.54.03-300x225.jpeg 300w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.54.03-768x576.jpeg 768w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.54.03-1200x900.jpeg 1200w, https:\/\/eequalspi.com\/wp-content\/uploads\/2017\/02\/2017-01-28-16.54.03.jpeg 1600w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/p>\n<p>Figure 3: 10mA, actually produced full scale.<\/p>\n<p>Also noteworthy here was that the striking voltage is above the max. Taking a closer look at voltages, the voltage between the anode and the indicating cathode when the tube is at 0 scale is 111V. When I drive it to full scale, it rises to 139V. Reading the aforementioned datasheet correctly, the 0 scale drop across the anode to indicating cathode should be at max 99V &#8211; it was out of spec but not grossly so.<\/p>\n<p>The only thing I could think to do is adjust the HVPS to be drive them at a lower voltage (120V), but my recollection from when I breadboarded this was that they did not strike reliably below about 140V.<\/p>\n<p>&nbsp;<\/p>\n<p>Stay tuned for the realization, the follow up and the fix!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; About a month ago, I was watching TV. As usual my IN-13 VU-Meter was dutifully bouncing away with the dialog. Out of nowhere, one of the tubes made a &#8220;tink&#8221; sound and the current control went away &#8212; the tube stayed ignited, but the &#8220;bar&#8221; was stuck at the bottom. I noticed that the &hellip; <a href=\"https:\/\/eequalspi.com\/index.php\/2017\/02\/13\/wherein-the-tubes-go-tink\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Wherein the tubes go &#8216;tink&#8217;&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,3],"tags":[],"class_list":["post-38","post","type-post","status-publish","format-standard","hentry","category-in-13-vumeter","category-nixie"],"_links":{"self":[{"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/posts\/38","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/comments?post=38"}],"version-history":[{"count":6,"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/posts\/38\/revisions"}],"predecessor-version":[{"id":69,"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/posts\/38\/revisions\/69"}],"wp:attachment":[{"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/media?parent=38"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/categories?post=38"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/eequalspi.com\/index.php\/wp-json\/wp\/v2\/tags?post=38"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}